This study compared segment stability after bimaxillary orthognathic surgery, comparing poly(L-lactide-co-glycolide) with titanium osteofixation at 12 months follow up. Fifteen patients were osteofixated with poly(L-lactide-co-glycolide) copolymer, 30 with 2.0-mm titanium miniplates. Preoperative, postoperative, and 1-year follow-up lateral cephalograms were analyzed. Maxillary average advancement in resorbable plate osteosyntheses (+/- standard deviation) was (case numbers/titanium controls) 2.5 (+/- 1.0) mm; n = 7/5.4 (+/- 3.5)mm; n = 21, setback 2.2 (+/- 2.4) mm; n = 7/1.9 (+/- 1.8) mm; n = 8, elongation 6.5 (+/- 3.4) mm; n = 9/3.7 (+/- 5.2) mm; n = 14, intrusion 1.0 (+/- 0.7) mm; n = 5/3.3 (+/- 2.7)mm; n = 13, mandibular average advancement was 5.5 (+/- 3.7) mm; n = 4/6.3 (+/- 8.8) mm; n = 18, setback 11.2 (+/- 7.7) mm; n = 7/7.2 (+/- 3.2) mm; n = 12, mandibular angle enlargement 7.9 (+/- 2.4) degrees ; n = 9/7.9 (+/- 6.6) degrees ; n = 21, reduction 6.9 (+/- 2.6) degrees ; n = 4/6.3 (+/- 6.6) degrees ; n = 9. Changes in landmark position within the study and control groups differed significantly in paired t testing (P =.01); operative movements were comparable in between study and control groups (P = 0.5, two-sided t test), only maxillary advancement was significantly smaller (P = 0.04) within study cases. Absolute instability at advanced A-point was (study group/controls) 1.2 (+/- 0.8)/2.4 (+/- 2) mm; setback 1.8 (+/- 1.9) mm/2.5 (+/- 1.7) mm; elongation at anterior nasal spine (ANS) 2.0 (+/- 1.4) mm/3.1 (+/- 3.6) mm, intrusion 1.1 (+/- 1.1) mm/2.2 (+/- 1.5) mm; advancement instability at B-point was 2.6 (+/- 2.7) mm/5.1 (+/- 8.2) mm, setback 2.7 (+/- 2.6) mm/1.7 (+/- 2) mm; mandibular angle enlargement instability 2.4 (+/- 2.7) degrees /8.2 (+/- 9.6) degrees , angle narrowing 7.0 (+/- 5.4) degrees /4.2 (+/- 5.9) degrees . Absolute postoperative instability was not significantly different in between study and control groups (P = 0.3). Tested resorbable poly(L-lactide-co-glycolide) osteofixation proved to be as reliable in segment fixation as titanium; however, study and control groups were not matched; the study group was small and therefore the results (especially advancement) have to be interpreted as preliminary until larger prospective cohorts become evaluated.
No takes yet. Share an insight, caveat, or question.
Landes et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: