Answers are grounded in this paper and cite their sources.
The effect of a recessed liquid oxygen tube in shear coaxial injection has been investigated experimentally using an optically accessible subscale rocket combustor operated at pressures between 40 and 60 bar. Different single-shear coaxial injectors have been used to inject liquid oxygen and methane at relevant operating conditions covering sub-, near-, and supercritical pressures with respect to the critical point of oxygen. Liquid oxygen was injected at 120 K and the injection temperature of gaseous methane was about 275 K. Detection of spontaneous OH and CH chemiluminescene has been performed to characterize the flame-anchoring zone near the liquid oxygen post tip. In addition, the influence of the injector geometry on the combustion roughness and stability has been investigated during steady-state operating points. An increased flame expansion was observed with a recessed injector element. At low momentum flux ratio, the pressure drop accross the injector increases with a recessed liquid oxygen tube compared with a flush tube. Furthermore, a recessed liquid oxygen tube led to be a smoother combustion in general; however, this configuration also led to additional resonant frequencies in the chamber acoustics.
No takes yet. Share an insight, caveat, or question.
Lux et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: