Numerical simulation reveals modest peak temperature reductions with nano-enhanced phase change material jackets in lithium-ion batteries, highlighting limited thermal protection during high-rate...
Passive thermal management of lithium-ion cells using phase change material (PCM) jackets is limited by the low thermal conductivity of paraffin carriers. This work develops and verifies a numerical framework for transient conduction and melting in nano-enhanced PCM (NePCM) jackets. A two-dimensional finite-volume solver models a prismatic cell with two paraffin RT42 jackets on its large faces using a fixed-grid apparent-heat-capacity formulation; non-uniform tab-weighted heat generation renders the field genuinely two-dimensional. Effective properties follow volume-fraction mixture rules, and graphene nanoplatelets (GNP), CuO and Al 2 O 3 are compared at 2, 5 and 10 wt%. A physics-informed neural network (PINN) solves the one-dimensional through-thickness sub-problem and is verified against the finite-volume solver, which itself reproduces the analytical two-phase Stefan solution to within a 0.15 mm front error and a 0.17 K root-mean-square error (RMSE); the PINN matches the one-dimensional field with RMSE below 0.32 K and maximum deviation 0.40 K. All parametric battery results are finite-volume solutions; the energy balance closes to within 0.1%. At 30 C ambient, a 5 wt% GNP jacket lowers the peak cell temperature by 0.6 C at 2 C and 0.9 C at 3 C. The extrapolative 10 wt% case gives a 1.2 C reduction at 2 C and 30 C, with a maximum reduction of 1.8 C at 3 C and 35 C ambient; GNP gives the largest peak-temperature reduction within the selected mean-field property model, a ranking that is model-dependent rather than experimentally established. For the primary 5 wt% GNP case, the peak still exceeds the 55 °C reference threshold at 2 C and 35 C ambient and under all investigated 3 C conditions, so nanoparticle enhancement reduces but does not eliminate the high-rate exceedance of that reference threshold; these reductions (0.3–0.9 C at 5 wt%) are small relative to the model uncertainties and should be read as a modest, conditional improvement rather than a decisive safety solution. Absolute temperatures remain conditional on the assumed heat-generation model, whose reversible-heat term dominates the sensitivity. The PINN is used only for the one-dimensional through-thickness verification case; the study is a numerical verification exercise in which the solvers are cross-checked against an analytical solution and against each other, all reported temperatures are model predictions.
No takes yet. Share an insight, caveat, or question.
Alqurashi et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: