This letter demonstrates dramatic improvements in flow rate and frequency range over conventional planar ac electro-osmotic (ACEO) pumps by exploiting three-dimensional (3D) stepped electrodes. A 3D ACEO pump was fabricated by electroplating steps on a symmetric electrode array and tested against a state-of-the-art asymmetric planar ACEO pump in a microfluidic loop. For all frequencies (0.1–100kHz), the 3D pump had a faster flow rate, in some cases by an order of magnitude. Their experimental results suggest that, after some optimization, mm/s velocities will be attainable with alternating battery voltages, which presents an exciting opportunity for microfluidics.
No takes yet. Share an insight, caveat, or question.
Urbanski et al. (2006) studied this question.