In the alternative current field measurement (ACFM) technique, the nonzero value of liftoff distance for the magnetic sensor acts as a low-pass filter on surface crack signals, causing errors in crack detection and sizing. We present a blind deconvolution algorithm for liftoff evaluation and surface crack signal restoration. The algorithm employs the available closed-form expressions for the distribution of electromagnetic fields at the metal surface in the vicinity of a crack. To examine the accuracy of the algorithm, we use the original and the restored signals for crack sizing by a wavelet network inversion method. We present simulated and experimental results to demonstrate the role of the proposed algorithm in improving the inversion process.
No takes yet. Share an insight, caveat, or question.
Amineh et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: