Answers are grounded in this paper and cite their sources.
We have measured the terminal level lifetime (τ11/2) for the 1-μm neodymium transition in several laser media, using a novel pump (2.41-μm) and probe (1.06-μm) technique. This method allows us to populate the 4I13/2 level directly and subsequently to monitor the terminal level 4I11/2 population as a function of time by observing the change in integrated fluoresence of the 0.88-μm emission for each time delay between the pump and the probe pulses. We developed a computer model to analyze the data and determined the upper and lower limits for the τ11/2 lifetime. The results for some of the materials investigated are 115–225 ps for Nd:Y3Al5O12, 250–450 ps for Nd:LG-750 (phosphate glass), 535–740 ps for Nd:LG-660 (silicate glass), 896–1900 ps for Nd:YAlO3, and 10.5–20 ns for Nd:YLiF4. In addition, we found the lifetimes to be independent of the neodymium doping concentration for the phosphate and silicate glass samples investigated.
No takes yet. Share an insight, caveat, or question.
Bibeau et al. (1995) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: