Why the study?
Does high sensitivity cardiac troponin T measurement help in diagnosing myocardial ischemia in patients undergoing stress testing?
Does high sensitivity cardiac troponin T measurement help in diagnosing myocardial ischemia in patients undergoing stress testing?
Answers are grounded in this paper and cite their sources.
High sensitivity cardiac troponin T increases in most patients undergoing stress testing regardless of the presence of ischemia or coronary artery disease, making it an unreliable marker for detecting transient ischemia.
BACKGROUND: Cardiac troponin is the most sensitive marker of myocardial injury, but controversy still exists about its role in detecting ischaemia. METHODS: To investigate the role of troponin as a marker of stress-induced ischaemia, circulating high sensitivity cardiac troponin T (hs-cTnT) was measured and compared with the MB fraction of creatine kinase (CK-MB) in 125 patients undergoing a stress test (53 electrocardiogram/echo exercise, 42 echo dipyridamole and 30 echo dobutamine tests). RESULTS: Plasma concentrations of hs-cTnT increased after the tests in 90/125 patients, while an increase of CK-MB was seen in 31/125 patients ( p<0.0001). Overall, hs-cTnT significantly increased from 17.5±16.9 ng/l to 25.5±27.9 ng/l ( p<0.0001), without significant changes of CK-MB. Significant increments in hs-cTnT were documented after exercise test (from 15.9±11.9 ng/l to 19.5±13.6 ng/l, p<0.0001) and dobutamine test (from 20.6±20.8 ng/l to 37.8±31.1 ng/l, p=0.0006), in absence of changes in CK-MB according to each stressor. Among the 125 tests, 84 were diagnosed as negative and 41 as positive for myocardial ischaemia. Significant increments in hs-cTnT were detected after both negative (from 18.6±19.2 ng/l to 27.1±32.1 ng/l, p=0.0018) and positive test (from 15.2±10.8 ng/l to 22.3±16.2 ng/l, p=0.0005), without significant changes of CK-MB according to the test result. Despite a positive correlation between stress-induced increase of hs-cTnT and obstructive coronary artery disease, the release of troponin was observed also in a significant proportion of patients without coronary stenoses. Left ventricular hypertrophy markedly enhanced myocardial release of troponin. CONCLUSIONS: Circulating troponin increases in most patients undergoing a stress test, irrespective of the test result and of coronary artery disease. Plasma release of troponin depends on multiple pathogenetic mechanisms, making the biomarker a not reliable tool in detecting transient ischaemia.
No takes yet. Share an insight, caveat, or question.
Orsini et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: