Optical interferometric measurements which determine the equation of state of xenon in the neighborhood of the critical point are described. Analysis of Fraunhofer interference patterns from a thin slab of fluid yields data pairs: optical phase ψ₊=ρ-κTμ and isothermal compressibility κT, along isotherms in the temperature range -10^-4<ε<10^-4, where ε=(T-Tc)Tc. Experimental data are analyzed in terms of a new parametric transformation of thermodynamic variables, based on the static scaling hypothesis of Widom, which requires that dlnψ₊dlnκT=-(βγ)W(θ), where θ=εκT^1γ. On the critical isotherm, ε=0, we expect that lnψ₊=const-(βγ)lnκT. This accords with observation and yields a sharp determination of Tc which is decoupled from other parameters. The data are well represented by the bilinear form W(θ)=(1-θθₓ)(1-θθ₀) where θ=θ₀ on the critical isochore and θₓ on the coexistence boundary. This is integrated to yield the parametric equation of state ψ₊=Y₀^βR^β(1-θθ₀)^βΔ, where R=κT^-1γ. A six-parameter fit to 1200 data points yields Tc=Tc(lab)±0.0001^∘C, β=0.3583±0.0002, γ=1.2296±0.0005, θ₀=0.1101±0.0003, Y₀^β=0.4203±0.0004, and Δ=3.869±0.001. This implies βΔ=1.386±0.001, which differs significantly from the value βΔ=3/2 implied by a five-parameter transformation suggested by Ho and Litster. The coexistence curve is measured in the range 10^-5<|ε|<5×10^-2, and fitted by the power law (ρL-ρGρc=B(-ε)^β, with the result β=0.344±0.003 and B=3.51±0.05. Systematic deviations indicate that β increases for large |ε|. A fit with the form ${({{ρ}}L{-}{{ρ}}G)}{{{ρ}}c}=B{({-}{ε})}^{{β}}+A{({-}{ε})}^{{{β}}^{{'}}}$ yields significant improvement, with ${β}=0.332±{}0.001$, $B=3.042±{}0.03$, ${{β}}^{{'}}=0.61±{}0.02$, and $A=0.93±{}0.04$. The disagreement between this ${β}$ and the ${β}$ obtained from fitting the Fraunhofer data will be discussed in the text. The coefficient of isothermal compressibility on the critical isochore ${P}c{K}T$ is measured in the range $2.7×{}{10}^{{-}5}<{ε}<4×{}{10}^{{-}2}$, and fitted by the equation ${{κ}}T={P}c{K}T={Γ}{{ε}}^{{-}{γ}}$. Over the measured range, the data indicate ${γ}=1.260±{}0.002$ and ${Γ}=0.056±{}0.001$. There is evidence that ${γ}$ depends on the range of fit, and we find ${γ}=1.232±{}0.006$ for ${ε}<{10}^{{-}3}$, which agrees well with the ${γ}$ determined from the near-critical Fraunhofer data.
No takes yet. Share an insight, caveat, or question.
Estler et al. (1975) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: