Key points are not available for this paper at this time.
Design
Review
Answers are grounded in this paper and cite their sources.
Platelet bioenergetics and biomechanics may complement function testing; leaves open validation against clinical outcomes.
The purpose of this review is to explore the relationship between platelet bioenergetics and biomechanics and how this relationship affects the clinical interpretation of platelet function devices. Recent experimental and technological advances highlight platelet bioenergetics and biomechanics as alternative avenues for collecting clinically relevant data. Platelet bioenergetics drive energy production for key biomechanical processes like adhesion, spreading, aggregation, and contraction. Platelet function devices like thromboelastography, thromboelastometry, and aggregometry measure these biomechanical processes. Platelet storage, stroke, sepsis, trauma, or the activity of antiplatelet drugs alters measures of platelet function. However, the specific mechanisms governing these alterations in platelet function and how they relate to platelet bioenergetics are still under investigation.
No takes yet. Share an insight, caveat, or question.
George et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: