This paper presents a novel non-contact vibration-monitoring technique based on transient measurements from a Fabry–Perot interferometric displacement sensor implemented using single-mode fibre. Two different extrinsic sensor configurations are demonstrated using one-fibre and two-fibre arrays of 4/125 µm single-mode fibre butted with a gradient-index lens. The design concept, mathematical modelling and results are demonstrated. The sensor configurations exploit fringe discrimination over multiple orders. A working range up to 14 µm is demonstrated for the measurement of vibration amplitude at 1 kHz excitation using the one-fibre configuration. Similar tests using the two-fibre configuration indicated a displacement measurement up to 65 µm and vibration measurement up to 7 µm at 2.5 kHz. The two-fibre configuration is also assessed in conjunction with an absolute scheme for the measurement of vibration using dual-wavelength signal processing. In this scheme, two wavelength signals are captured from the sensing interferometer to provide unambiguous measurement of vibration direction.
No takes yet. Share an insight, caveat, or question.
Tarun Kumar Gangopadhyay (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: