A measuring system for magnetostriction of silicon steel sheet using optical methods and a single sheet tester has been developed to establish a standard test method for IEC and JIS. Various factors affecting measurement accuracy and reproducibility of the developed system are examined. Two optical instruments, such as a laser Doppler vibrometer and a heterodyne displacement meter, are compared. 3-D characteristics of magnetostriction under ac excitation in the rolling direction are measured up to 2.0 T.
No takes yet. Share an insight, caveat, or question.
Nakase et al. (1998) studied this question.