During the fabrication of freestanding micromechanical structures, the structures must often be attached to the substrate to prevent movement, particularly during the release process. The attachments are then removed, freeing the structures from the substrate when they are to be used. Tethers are long thin beams that mechanically anchor freestanding structures to the substrate during fabrication, but are easily broken afterwards. This paper focused on fuse-tether designs and the associated technique used to break the tethers, Joule heating. The breaking characteristics of two fuse-tether designs were investigated using different current pulses. For each design, the current pulse that produced the most desirable electrical and mechanical break was chosen for reliability testing. The reliability tests resulted in a 100% success rate. However, molten silicon splattered undesirably in 20% of the cases. In addition to empirical testing, ANSYS® was used to simulate the Joule heating process. The ANSYS® model produced results that closely matched the break characteristics observed in the empirical tests. This research demonstrated that a fuse-tether can be severed reliably with the Joule heating technique, and the fuse-breaking characteristics can be predicted by modeling.
No takes yet. Share an insight, caveat, or question.
Chiu et al. (2006) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: