X-ray W/B multilayer mirrors with a period of 2.5 nm were deposited by dc magnetron sputtering and studied in comparison with W/Si multilayer systems of the same period. Transmission electron microscopy, grazing incidence X-Ray reflectivity, and x-ray photoelectron spectroscopy analysis revealed that the layer quality and interfaces of the W/B multilayers are not better than those of the W/Si multilayers. Strong intermixing between W and B is present, which leads to compound formation with little or no pure W left after the interaction: an optically unfavorable boride formation and an increased roughness result in a reduced reflectivity. The deposited W/B multilayer mirrors showed a reflectivity of 34.5% at 0.84 nm and angle of incidence 9.7°, compared to 40% obtained for W/Si multilayers. Ion polishing applied on the boron layers did not result in improvements of the reflectivity.
No takes yet. Share an insight, caveat, or question.
Medvedev et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: