BACKGROUND: Uterine arteriovenous malformations (AVMs) are known to spontaneously regress. PURPOSE: To assess the predictive value of ultrasonography for patients requiring conservative treatment for pregnancy related to AVMs. MATERIAL AND METHODS: Our prospective study included 75 patients (conservative management:therapeutic management = 45:30) with vaginal bleeding from pregnancy-related AVM. Clinical and ultrasonography examinations were reviewed, and the following information was gathered: complete blood count, AVM maximal diameter, AVM echogenicity, retained product of conception, number of blood vessels, and spectral Doppler (pulsatility index [PI], resistance index [RI], peak systolic velocity [PSV], time-averaged maximum velocity [TAMXV]). The Doppler criteria by Timmerman (mean PSV >70 cm/s: therapeutic management, mean PSV < 52 cm/s: conservative management) were used for the initial management selection. The association between experimental variables and outcomes was assessed to determine their usefulness for predicting conservative management. RESULTS: Features strongly associated with conservative management and their accuracy were PSV 89.6%, hemoglobin 84.7%, RI 83.1%, TAMXV 79.3%, and PI 78.6%. The overall accuracy for correct outcome classification was 64 (85.3%) of 75 patients. Most patients with conservative management had quicker improvement of symptoms and spontaneous regression at follow-up. CONCLUSION: Ultrasonography can accurately predict selection of conservative management.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2013) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: