We evaluated the sweat-patch test for its ability to detect alcohol consumption. During an 8-day study, volunteers drank whisky while wearing sweat-patches that collected sweat continuously at a steady rate. We offered 1.0, 2.0, or 5.0 g ethanol/kg/day to 6 continuous drinkers, and 5.0 g ethanol/kg/day for 2 days to 8 episodic drinkers, and removed sweat patches after 2, 4, 6, and 8 days. The concentration of ethanol in the collected sweat (Cs) rose: (1) progressively with the amount of alcohol consumed: and (2) linearly with the mean concentration of ethanol in the blood (Cb) during the sweat collection period (In Cs = 0.80 In Cb - 1.40; r = 0.93, p < 0.001). The test clearly distinguished drinkers from nondrinkers (Cs < 0.0022 G/L when no ethanol consumed; Cs > 0.0067 G/L when 0.5 G ethanol/kg/day consumed and when Cb > 0.013 G/L). The sweat patch test provides an objective index of drinking behavior with potential applications in clinical practice and research.
No takes yet. Share an insight, caveat, or question.
Phillips et al. (1980) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: