We report an investigation of the electrical activation of aluminum implanted at high dose in 4H–SiC. We show that at reasonably high temperature implantation and annealing conditions, one activates about 37.5% of the implanted species. Of course, the final (concentration-dependent) activation ratio differs slightly from this average value but varies only between 0.5 and 0.25 when the targeted concentration increases from 3.33×1018 to 1021 cm−3. Provided a standard mobility can be maintained, this results in fairly low sheet resistance. The best (lowest) value obtained in this work is 15 mΩ cm at 700 K (95 mΩ cm at room temperature) for a 190-nm-thick layer implanted with 1021 atoms cm−3. In MESA-etched p–n junctions with a 100 μm diameter, this resulted in a typical on-resistance of 1.5 mΩ cm2, mainly limited by the substrate and n− epitaxial layer.
No takes yet. Share an insight, caveat, or question.
Bluet et al. (2000) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: