In this article, an improved dc capacitor voltage balancing control is proposed for single-phase cascaded H-bridge (CHB) multilevel converters. Compared with conventional voltage balancing control methods, the proposed scheme has a comprehensive consideration of three aspects while balancing the capacitor voltages among H-bridges: coupling effect elimination, reactive power balancing, and dynamic performance improvement. First, the system mathematical model in thed–qreference frame is derived, and the relationship among duty cycle modifications of H-bridges is revealed to eliminate the coupling effect of voltage balancing control on the current control loop. Then, based on the H-bridge power model, a quantitative solution for reactive power balancing is presented to design the reactive duty cycle modifications. In order to enhance the dynamic performance of voltage balancing control, a dynamic references design method is adopted to evaluate the active duty cycle modifications. Finally, both simulation and experimental results are presented to validate the effectiveness of the proposed scheme.