Because the kidneys are usually not visualized on radioiodine whole-body scans, the renal uptake can be mistaken for a thyroid cancer metastasis. The authors report the prevalence and characteristics of radioiodine retention in the kidneys and review the reported causes of false-positive radioiodine uptake in the abdomen and pelvic areas. Radioiodine uptake in the renal bed was noted on 9 of 400 (2.2%) I-123 diagnostic whole-body scans performed over a 7-month period in our center. The uptake was noted more clearly on posterior views, cleared on delayed images after further hydration, and was not consistently present on follow-up scans. It was unilateral and mimicked a renal or adrenal metastasis in 44% of the scans. In three cases, the uptake was associated with a dilated calyx, an extrarenal pelvis, or a voluminous pelvis. False-positive radioiodine uptake in the abdomen and pelvis has been previously reported in association with 14 different conditions. However, renal retention may represent the most common cause of false-positive radioiodine uptake in the abdomen pelvis. Delayed imaging after additional hydration is usually sufficient to clarify its origin.
No takes yet. Share an insight, caveat, or question.
Bakheet et al. (1996) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: