Detailed experimental studies have been carried out to determine the diffusion time, t m , at which the eddy current due to the defect is maximum for the defects located at different depths below the top surface of a stack of aluminum plates. These subsurface defects were detected using a transient eddy current non-destructive evaluation system based on a fluxgate sensor with differential excitation coil in the form of a double ‘D’. The diffusion time, t m, directly provides information about the depth of the defect and therefore has been evaluated for defects located at different depths from 2 to 20 mm below the top surface of the plate. The defect depth was varied in steps of 2 mm, while the overall total thickness of the stack of plates was kept constant at 21.5 mm. Each defect represented a localized loss of conducting volume, which was 70 mm in length, 1 mm in width and 1.5 mm in height. The experimental results show that the square root of the diffusion time t m is proportional to the depth of defect. In this system, the full sensitivity of the fluxgate sensor (0.5–1 nT) has been realized in a relatively noisy laboratory environment using an intelligent data acquisition system with built-in software.