We have investigated radiation induced absorption in Al-doped, P-doped and Ge-doped optical fibres under60Co source gamma-radiation up to a total dose of 71 kGy at two temperatures 30 and 80°C. The Al-doped and P-doped fibres demonstrated high radiation sensitivity required for the optical fibre dosimetry. The RIA response to temperature increase from 30 to 80°C depended on the dopant. In Al-doped fibres the absorption level decreased by 25% whereas in P-doped fibres it increased by at least 10%. For comparison we also tested standard telecom-grade Ge-doped fibres. Such fibres demonstrated a monotonous rise of the RIA during the whole irradiation with a small decrease of sensitivity at the higher temperature.
No takes yet. Share an insight, caveat, or question.
Faustov et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: