Key result
Targeted fine-tuning of ECG foundation models boosts ICU AF detection F1 score to 0.83.
Why the study?
It was unknown how well self-supervised ECG foundation models perform in detecting atrial fibrillation and sinus rhythm during continuous monitoring of intensive care unit patients.
Does targeted fine-tuning of ECG foundation models improve the classification of atrial fibrillation and sinus rhythm in ICU patients compared to off-the-shelf models?
Does targeted fine-tuning of ECG foundation models improve the classification of atrial fibrillation and sinus rhythm in ICU patients compared to off-the-shelf models?
Answers are grounded in this paper and cite their sources.
Off-the-shelf pre-trained ECG foundation models do not generalize well to continuous ICU monitoring, but targeted fine-tuning on high-quality data significantly improves their performance for detecting atrial fibrillation and sinus rhythm.
Background Recent advances in deep learning have led to the development of ECG foundation models (ECG-FMs) trained with self-supervised learning, which can extract generalizable representations from large-scale data. In this study, we evaluated the performance of these ECG-FMs in detecting atrial fibrillation and sinus rhythm during continuous monitoring of intensive care unit (ICU) patients, using data from Amsterdam University Medical Center (Amsterdam UMC). Our three-stage study: (i) used within-dataset classification performance on public PhysioNet datasets as an indirect proxy for label consistency, (ii) tested off-the-shelf fine-tuned ECG-FMs on ICU data, and (iii) fine-tuned ECG-FM on curated public datasets, with and without weakly labelled in-house ICU data. Results Off-the-shelf model showed limited transferability (F1 = 0.68 for sinus rhythm (SR), 0.52 for atrial fibrillation (AF)). Fine-tuning on consistent public datasets achieved robust performance (F1 = 0.91 for SR, 0.82 for AF), while adding weakly labelled ICU data further improved recall at some cost to precision. Performance remained stable across varying ECG lead configurations, supporting adaptability to heterogeneous inputs. Conclusions These findings indicate that off-the-shelf pre-trained ECG-FMs do not generalise well to continuous monitoring in ICU populations; however, after targeted fine-tuning, they can achieve strong performance even in unseen cohorts, underscoring the importance of high-quality fine-tuning data and rigorous local validation.
No takes yet. Share an insight, caveat, or question.
Galanty et al. (2026) studied Atrial fibrillation and sinus rhythm (n=226). Fine-tuned ECG foundation models vs. Off-the-shelf pre-trained ECG foundation models was evaluated on F1 score for atrial fibrillation detection. Targeted fine-tuning of ECG foundation models improved atrial fibrillation detection in ICU patients from an F1 score of 0.52 with off-the-shelf models to 0.83.
Synapse has enriched 10 related papers. Consider them for comparative context: