Clinical outcomes of two generations of pericardial bioprostheses in concomitant aortic valve and coronary artery bypass graft surgery needed evaluation.
Does rapid-deployment aortic valve replacement compared to standard aortic valve replacement improve 5-year survival in patients undergoing concomitant aortic valve replacement and coronary artery bypass graft surgery?
Does rapid-deployment aortic valve replacement compared to standard aortic valve replacement improve 5-year survival in patients undergoing concomitant aortic valve replacement and coronary artery bypass graft surgery?
Answers are grounded in this paper and cite their sources.
Rapid-deployment and standard pericardial bioprostheses provide equivalent 5-year survival and clinical outcomes in concomitant aortic valve replacement and CABG, despite shorter surgical times with rapid-deployment valves.
OBJECTIVES: Clinical outcomes of 2 generations of pericardial bioprostheses in concomitant aortic valve and coronary artery bypass graft surgery were analysed. METHODS: Patients were recruited from 2 European centres and divided into 2 groups based on the type of aortic bioprosthesis used: Edwards Intuity Elite™ rapid-deployment (RD) bioprostheses or standard Edwards Magna Ease (ME). A propensity score weighting approach was used for data analysis. RESULTS: A total of 285 patients were included: 144 (50.5%) in the RD group and 141 (49.5%) in the ME group. Thirty-day mortality was 2.8% (RD) and 5% (ME) (P = 0.09). Significantly shorter times of aortic cross-clamp and cardiopulmonary bypass were observed in the RD cohort [94 vs 120 min (P < 0.001); 128 vs 160 min (P < 0.001)]. The RD group was associated with a lower median transvalvular gradient at discharge and follow-up (both P < 0.001). However, 5-year survival was not different, being 93% in RD patients and 91% in the ME group [hazard ratio 0.89 (95% confidence interval: 0.38-2.09), P = 0.784]. The 5-year cumulative incidence of combined events (including percutaneous coronary interventions, endocarditis, thromboembolic events, rehospitalizations and bleeding) favoured the ME group [16.1% (RD) vs 7.3% (ME)] [hazard ratio 2.38 (95% confidence interval:1.03-5.52), P = 0.043]. However, this turned similar when the Cox model analysis was adjusted for revascularization variables (P = 0.067). CONCLUSIONS: RD and ME pericardial bioprostheses used in concomitant aortic valve replacement and coronary artery revascularization provide equivalent clinical and haemodynamic 5-year outcomes, despite constant lower transvalvular gradients and shorter surgical operating times observed with RD technology.
No takes yet. Share an insight, caveat, or question.
Bottio et al. (2022) studied this question.