A robust field-weakening method for direct-torque-controlled (DTC) synchronous reluctance motors is presented in this paper. The proposed algorithm achieves smooth transition between the constant torque and field-weakening regions. Maximum torque per ampere is utilized below base speed, while both the current and voltage limits of the drive system are satisfied in the field-weakening region. The proposed method is robust to the variations in the machine dq -axis inductances. This ensures the system stability during field-weakening operation, especially along the maximum torque per flux trajectory. The proposed algorithm is incorporated into the duty ratio regulation-based DTC to achieve high-performance torque and flux control in the field-weakening region. Experimental results included in this paper confirm the veracity of the proposed method.
No takes yet. Share an insight, caveat, or question.
Foo et al. (2016) studied this question.