Discharge lag in pick-up tubes, particularly of modern cathode-potential-stabilized type, and its relation to the acceptance of the electron beam by the target are analysed. Measurements of beam acceptance as a function of target potential reveal effective beam temperatures substantially equal to cathode temperature at low beam currents, but higher and multi-valued at high currents. These temperatures set a limit to the possible reduction of lag without target biasing; this limiting lag, referred to as Maxwellian lag, is calculated and presented graphically. Direct measurements of lag are compared with the limiting values. Target biasing, the application of a small positive potential to the target face, reduces this limitation. Results of electron-optical measurements, throwing some light on the anomalous beam temperatures, are presented.
No takes yet. Share an insight, caveat, or question.
Meltzer et al. (1958) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: