This letter presents the design, fabrication, and testing of a diaphragm-based, all-silica fiber tip pressure sensor. A piece of 1.2-μm-thick silica diaphragm was thermally bonded to the end face of an etched fiber with an outer diameter (OD) of 125 μm to form a Fabry-Perot (FP) interferometer. The diameter of the etched FP cavity is 105 μm, enabling the sensing area to be large, and thus, a static pressure sensitivity of 12.4 nm/kPa (85.3 nm/psi) is accomplished without the need for any post polishing or etching. The sensor also shows a low-temperature cross sensitivity during tests, owing to its all-silica structure. It is suitable for extensive production, and it has a great potential to work in applications, where miniature size and high sensitivity are essential such as medical applications.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: