A ray-tracing code has been developed, and the design parameters of the laser pump head were analyzed in terms of crystal diameter, doping concentration, and optical cavity diameter. According to the numerical analysis, we fabricated an efficient diode-pumped Nd:YAG laser and experimentally obtained 500-W output power. The output power is close to the numerically calculated output power of approximately 450 W and corresponds to an optical-to-optical conversion efficiency of 46.7% and an optical slope efficiency of 49%.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2002) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: