Does color-coded duplex ultrasound improve the detection of internal carotid pseudo-occlusion compared to intraarterial angiography in patients with suspected occlusion?
Does color-coded duplex ultrasound improve the detection of internal carotid pseudo-occlusion compared to intraarterial angiography in patients with suspected occlusion?
Color-coded duplex ultrasound using low-pulse repetition frequencies may be superior to angiography for differentiating pseudo from complete carotid artery occlusion.
May aid detection of carotid pseudo-occlusion missed by angiography; hypothesis-generating case report requiring prospective validation.
The differentiation of “pseudo” from complete carotid artery occlusion is still widely considered to be an indication for intraarterial angiography. The authors report a case in which color-coded duplex ultrasound revealed a persisting string-like lumen that was not adequately demonstrated by angiography. The duplex diagnosis of “pseudo” occlusion requires the use of low-pulse repetition frequencies and in future may reduce the need for invasive imaging techniques. If angiography is undertaken, even delayed films may fail to demonstrate the residual lumen adequately.