Answers are grounded in this paper and cite their sources.
The systematic, objective evaluation of incontinence after artificial urinary sphincter placement is critically important in the direction of further therapy. The technique and application of perfusion sphincterometry in the evaluation of 9 men with various causes of incontinence after artificial sphincter implantation are described. The perfusion sphincterometry study, which does not require sophisticated urodynamic equipment, helped to define clearly the cause of the incontinence and, thus, facilitated appropriate therapy.
No takes yet. Share an insight, caveat, or question.
Gary E. Leach (1987) studied this question.