BACKGROUND: Management of intestinal fistulae in open abdominal wounds remains a significant clinical challenge for those caring for patients surviving damage control abdominal operations. Breaking the cycle of tissue inflammation, infection, and sepsis, resulting from leakage of enteric contents, should be a major goal in the approach to these complex patients. We describe a technique utilizing vacuum assisted closure (VAC) which achieves control of enteric flow from fistulae in open abdominal wounds. METHODS: The fistula-VAC is fashioned from standard sponge supplies, negative pressure pumps, and ostomy appliances. The fistula-VAC was changed every three days prior to split thickness skin grafting, and every five days following grafting. RESULTS: Five patients underwent application of the fistula-VAC. All patients had complete diversion of enteric contents. This enteric diversion allowed for successful skin grafting in all patients. CONCLUSION: Application of the fistula-VAC should be considered a useful option in treating patients with intestinal fistulae in open abdominal wounds.
No takes yet. Share an insight, caveat, or question.
Goverman et al. (2006) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: