Key result
Knitted hydrogel strain sensor enables continuous pulse tracking to distinguish cardiovascular disease risk.
Why the study?
Does an optimized knitted strain sensor with PAAm hydrogel adhesion improve the collection of pulse waveforms for distinguishing potential CVD risks in human patients?
Does an optimized knitted strain sensor with PAAm hydrogel adhesion improve the collection of pulse waveforms for distinguishing potential CVD risks in human patients?
An optimized textile-based wearable strain sensor with improved mechanical compatibility and adhesion can accurately monitor pulse waveforms to help identify cardiovascular disease risk.
Wearable electronics can achieve high-fidelity monitoring of pulse waveforms on the body surface enabling early diagnosis of cardiovascular diseases (CVDs). Textile-based wearable devices offer advantages in terms of high permeability and comfort. However, knitted strain sensors struggle to capture small-range deformation signals due to stress dissipation during friction and slip of yarns within the textiles. They are optimized for mechanical adaptability and adhesive capability. In this work, the stitch configurations of knitted structure are adjusted to optimize the energy dissipation ratio during deformation and waveform fitting performance. These electric-mechanical results enabled the selection of the most suitable knitted structure for the clinical diagnosis. On the other hand, the sensor's adhesion is optimized with respect to electrical-force-strain coupling and energy transfer efficiency at the interface between skin and sensor. The balance between the storage modulus and loss modulus are adjusted via the crosslinking degree of the polyacrylamide (PAAm) hydrogel network. As a result, the optimized knitted sensor enables stable collection of pulse waveforms from the radial and dorsalis pedis arteries. In human patient evaluations, the knitting-based strain sensor can distinguish patients with different potential CVD risks through extracted characteristic indicators.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2025) studied Cardiovascular diseases. Optimized knitted strain sensor with PAAm hydrogel was evaluated on Collection of pulse waveforms and distinguishing patients with different potential CVD risks. An optimized knitting-based strain sensor with adjusted stitch configurations and polyacrylamide hydrogel adhesion enabled stable collection of pulse waveforms to distinguish patients with CVD risks.