Thirty-six superficial digital flexor tendons from nine fresh equine cadavers were transected and sutured with size 2 monofilament nylon. Nine tendons were repaired with each of four suture patterns: single-locking loop, double-locking loop, triple-locking loop, or three-loop pulley. The times required for application, tensile strengths, resistance to distraction (gap), and modes of failure were analyzed. The mean times required were: single-locking loop, 3 mins, 15 secs; double-locking loop, 4 mins, 15 secs; triple-locking loop, 10 mins, 50 secs; and three-loop pulley, 4 mins. The double-locking loop, triple-locking loop, and three-loop pulley suture patterns were stronger than the single-locking loop. The triple-locking loop and three-loop pulley patterns were close in strength and only the triple-locking loop was stronger than the double-locking loop. The three-loop pulley had the greatest resistance to gap formation and its mode of failure was different from the others. The three-locking loop suture patterns failed by suture breakage but the three-loop pulley failed first by suture pull-out and then by suture breakage.