Testing of outdoor insulators in a fog chamber is universally used. Many factors affect the generation of fog. Fog parameters such as the pressure of the compressed air and the water flow rate feeding the nozzles to form the fog, as well as the size and the speed of the fog droplets impinging on the surface of the insulators, play a major role in the outcome of electrical performance tests. In order to be able to compare test results from different laboratories, the conditions of fog generation should be defined unambiguously and clearly. In the present paper relationships between air pressure, water flow rate and air speed which are related to the distribution and the speed of the fog droplets, are determined as a function of distance from the IEEE-IEC standard nozzles forming the fog. The distribution of different fog droplet sizes is measured. The influence of the fog parameters on the aging characteristics of surface resistance, surface roughness, leakage current and surface hydrophobicity of high temperature vulcanized (HTV) silicone rubber are presented.