This paper presents the fabrication, characterization, and application of a novel silicon-polymer laterally stacked electrothermal microactuator. The actuator consists of a deep silicon skeleton structure with a thin-film aluminum heater on top and filled polymer in the trenches among the vertical silicon parts. The fabrication is based on deep reactive ion etching, aluminum sputtering, SU8 filling, and KOH etching. The actuator is 360long, 125μ mwide, and 30thick. It generates a large in-plane forward motion up to 9at a driving voltage of 2.5 V using low power consumption and low operating temperature. A novel 2-D microgripper based on four such forward actuators is introduced. The microgripper jaws can be moved along both thex- andy-axes up to 17 and 11, respectively. The microgripper can grasp a microobject with a diameter from 6 to 40. In addition, the proposed design is suitable for rotation of the clamped object both clockwise and counterclockwise.[2007-0192]
No takes yet. Share an insight, caveat, or question.
Duc et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: