Key result
ACGI-based velocity field reconstruction produced data of comparable quality to accepted velocity data acquisition methods in in vitro models of pediatric cardiac vasculatures.
Population
in vitro models of surgically corrected pediatric cardiac vasculatures
Comparison
adaptive control grid interpolation based… vs accepted velocity data acquisition methods
Design
Preclinical
Authors
Loading...
ACGI reconstruction enables 3D velocity data from 2D MR slices in pediatric models; extends computational flow analyses but leaves clinical translation open.
ACGI-based velocity field reconstruction can approximate missing inter-slice MR image data, providing suitable 3D velocity data for computational analyses of flow fields.
Frakes et al. (2004) studied Surgically corrected pediatric cardiac vasculatures (in vitro models). Adaptive control grid interpolation (ACGI) based velocity field reconstruction vs. Accepted velocity data acquisition methods was evaluated on Velocity field reconstruction quality. ACGI-based velocity field reconstruction produced data of comparable quality to accepted velocity data acquisition methods in in vitro models of pediatric cardiac vasculatures.