Answers are grounded in this paper and cite their sources.
We report on 790-nm diode-pumped continuous-wave and passively Q-switched Tm:CYA lasers. For continuous-wave laser operation, a maximum output power of 7.62 W is achieved with slope efficiency of 50.9%. Passive Q-switching of the Tm:CYA crystal is also obtained with a maximum average output power of 1.32 W using a Cr:ZnSe saturable absorber. The shortest pulse width is about 42.6 ns with a pulse energy of 60.2 μJ and a pulse peak power of 1.41 kW. These results represent the best laser performances of continuous-wave and passively Q-switched Tm:CYA lasers, to date. The 1.94-μm Tm:CYA lasers provide better laser sources for shallow absorption of biological tissue.
No takes yet. Share an insight, caveat, or question.
Lan et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: