Key result
Trans-oesophageal echocardiography-guided implantation of a cardiac resynchronization therapy pacemaker and atrioventricular node ablation was successfully performed after a TriClip procedure.
Why the study?
Tricuspid edge-to-edge intervention creates an obstacle for future right ventricular procedures such as CIED implantation, and reports of CIED management after this therapy are scarce.
Case Report (n=1)
TEE guidance enables safe CIED implantation and AV node ablation in patients with prior tricuspid edge-to-edge repair devices.
TEE guidance may enable safe CIED and AV node ablation after tricuspid edge-to-edge repair; leaves open need for prospective validation.
Background: Edge-to-edge intervention is the most common trans-catheter procedure performed for isolated severe tricuspid regurgitation in high-surgical-risk patients. However, it creates an obstacle for future right ventricular (RV) procedures such as implantation of cardiac implantable electronic devices (CIEDs). Reports of the management of CIED implantation after tricuspid edge-to-edge therapy are scarce. Case summary: A 76-year-old woman suffered from severe tricuspid regurgitation with New York Heart Association three symptoms despite optimal medical therapy. After a thorough evaluation, the heart team recommended the TriClip procedure as the treatment of choice. However, 12 months after a successful TriClip procedure, rapid atrial fibrillation needed to be addressed with CIED implantation and atrioventricular (AV) node ablation. Pre-procedural planning included the intended posterior location of the CIED to avoid interference with the implanted clip and future AV node ablation. With an additional left ventricular lead positioned anteriorly to the RV lead, the posterior position of the RV lead was secured. Under peri-procedural trans-oesophageal echocardiography (TEE), the planned procedures were performed successfully. Discussion: A blind manoeuvring of the RV lead may damage the edge-to-edge tricuspid device. In addition, friction due to an overly close contract between the RV lead and the edge-to-edge device may damage the RV lead. A successful and safe CIED implantation and atrioventricular node ablation can be performed after tricuspid edge-to-edge therapy with careful planning and its precise execution under TEE surveillance.
No takes yet. Share an insight, caveat, or question.
Tuohinen et al. (2023) conducted a case report in Severe tricuspid regurgitation and rapid atrial fibrillation (n=1). Trans-oesophageal echocardiography-guided implantation of a cardiac resynchronization therapy pacemaker and atrioventricular node ablation was evaluated on Successful CIED implantation and AV node ablation. Trans-oesophageal echocardiography-guided implantation of a cardiac resynchronization therapy pacemaker and atrioventricular node ablation was successfully performed after a TriClip procedure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: