Key result
2D contour LA reservoir strain strongly correlates with STE, underestimating peak strain by ~1%.
Why the study?
STE-derived left atrial reservoir strain has limitations including thin walls, anatomical discontinuities, and inter-vendor variability, prompting evaluation of a simplified 2D contour method.
Does the 2D contour strain method provide a reliable alternative to speckle-tracking echocardiography for assessing left atrial reservoir strain in patients with severe organic mitral regurgitation?
Observational (n=246)
Does the 2D contour strain method provide a reliable alternative to speckle-tracking echocardiography for assessing left atrial reservoir strain in patients with severe organic mitral regurgitation?
The 2D contour strain method is a highly feasible and reliable alternative to speckle-tracking echocardiography for measuring left atrial reservoir strain, which is especially useful for echocardiography labs lacking dedicated STE software.
STE limitations for LASr may affect diastolic assessment accuracy; leaves open dedicated LA strain validation in prospective studies.
BACKGROUND: Left atrial strain reservoir (LASr) has emerged as a useful parameter in assessing diastolic dysfunction and heart failure with preserved ejection fraction. LASr is typically assessed using speckle-tracking echocardiography (STE), which was developed to measure strain in the left ventricle. Despite its strength demonstrated in several clinical studies, the application of STE to the left atrium presents well-known limitations: thin walls, anatomical discontinuities, far-field location, and inter-vendor variability. The present study aims to evaluate the efficacy of an alternative method for assessing LASr, based on the percentage shortening of the atrial wall contour, by directly comparing it with STE-derived LASr values. METHODS: We retrospectively analyzed 246 patients in sinus rhythm with severe organic mitral regurgitation. The 2D contour strain method quantifies changes in the length of the two-dimensional (2D) endocardial atrial wall contour between end-systolic and end-diastolic frames. The peak strain value is calculated as: (maximum perimeter length-minimum perimeter length)/maximum perimeter length × 100. RESULTS: 2D contour strain measurements were feasible in all patients. A strong correlation was observed between STE-derived and 2D contour-derived LASr values, with an R-value of 0.93. On average, 2D contour strain measurements underestimated LA peak strain by approximately 1% compared to STE. The consistency of 2D contour LA strain measurements, as assessed by inter- and intra-observer reproducibility, was excellent. CONCLUSION: These findings suggest that 2D contour LA strain is a feasible and reliable alternative to STE for assessing LASr. This approach is particularly valuable in echocardiography labs where STE software for LA is unavailable.
No takes yet. Share an insight, caveat, or question.
Ingallina et al. (2026) conducted an observational in Severe organic mitral regurgitation (n=246). 2D contour strain method vs. Speckle-tracking echocardiography (STE) was evaluated on Correlation between STE-derived and 2D contour-derived LASr values (R=0.93). The 2D contour strain method for assessing left atrial reservoir strain strongly correlated with speckle-tracking echocardiography (R=0.93), underestimating peak strain by approximately 1%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: