An electrostatically actuated non-linear microelectromechanical systems (MEMS) resonator can describe double hysteresis behavior in the measured frequency response due to the interplay between electrical and mechanical non-linearities in the system. This paper provides the first experimental mapping of the stable and unstable branches of the frequency response of a MEMS resonator describing a double hysteretic frequency response using a closed-loop phase feedback oscillator. Furthermore, the frequency stability of the oscillator is compared for varying amplitude and phase feedback conditions, and it is experimentally demonstrated that parametric noise up-conversion can be suppressed in such a system by suitably biasing the resonator at one of the four bifurcation points in such a system. This result is qualitatively consistent with theoretical prediction and demonstrates that improved frequency stability in a non-linear MEMS oscillator is possible by suitably biasing the resonator using simultaneous amplitude and phase feedback.
No takes yet. Share an insight, caveat, or question.
Sobreviela et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: