This article addresses the varied possibilities for following a two-level fractional factorial with another fractional factorial half the size of the original experiment. Although follow-up fractions of the same size as an original experiment are common practice, in many situations a smaller followup experiment will sufIice. Peter John coined the term “semifolding” to describe using half of a foldover design. Existing literature does include brief mention and examples of semifolding but no thorough development of this follow-up strategy. After a quick examination of the estimation details for semlfoldmg the 24 – 1 IV design, we focus on following 16-run fractions with a semifold design of eight runs. Two such examples are considered—one in which the initial fraction ia resolution IV, the other resolution III. A general result is proven for semifolding 2 k – p IV designs. Conducting full foldover designs in two blocks is also recommended.
No takes yet. Share an insight, caveat, or question.
Mee et al. (2000) studied this question.