Experimental analysis demonstrates electron trapping mechanisms in high-power gyrotrons, suggesting specific gun design criteria to suppress operating instabilities.
A key parameter for the gyrotron operation and efficiency is the presence of trapped electrons. Two electron trapping mechanisms can take place in gyrotrons: (i) the adiabatic trap and (ii) the magnetic potential well. Their influence on the gyrotron operation is analyzed. Two gun design criteria are then proposed to suppress both mechanisms in order to minimize the risk of possible problems. Experimental results of three high power gyrotrons are presented and their performance is correlated to the presence of populations of trapped electrons. Finally, some very general gun design principles are presented for the limitation of harmful electron trapping.