Capillary electrophoresis-electrospray tandem mass spectrometry (CE-ESI/MS/MS) is a simple and highly sensitive method for quantifying seven urinary androgen glucuronides. The urine samples were diluted and filtered through a membrane filter, and the filtrate was injected into a CE-MS/MS system without further sample preparation steps such as extraction and derivatization. The calibration ranges were 0.01-5 microg/mL for glucuronides of androsterone and 11beta-OHAn-3G, and 5-500 ng/mL for glucuronides of 11-ketoAn, DHEA, testosterone, epitestosterone and DHT. The linearity of the method was 0.992-0.998, and the limits-of-detection at a signal-to-noise ratio of 3 were 5-10 ng/mL. The coefficients of variation were in the range of 4.0-9.0% for intra-day assay and 4.1-9.8% for inter-day assay. The proposed method may be applicable to metabolic profiling in both quantitative and qualitative analysis.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: