Key result
During intramedullary nailing of intertrochanteric fractures, the overall surgical glove perforation rate was 17.4%, and the perforation rate significantly increased with longer operative times.
Why the study?
Intraoperative glove perforations increase surgical site infection risk, prompting this study to determine glove perforation incidence and identify high-risk surgical steps during intramedullary nailing of intertrochanteric fractures.
What is the incidence and what are the risk factors for surgical glove perforation during intramedullary nailing of intertrochanteric fractures?
Observational (n=148)
No
What is the incidence and what are the risk factors for surgical glove perforation during intramedullary nailing of intertrochanteric fractures?
Intramedullary nailing of intertrochanteric fractures is associated with a high rate of surgical glove perforations (17.4% of gloves, 85.1% of surgeries), particularly during awl usage, locking screw insertion, and in surgeries lasting over 60 minutes.
Answers are grounded in this paper and cite their sources.
May indicate elevated SSI risk in intertrochanteric nailing; hypothesis-generating for targeted glove protocols, prospective trials needed.
Intramedullary nail fixation is a routine procedure for treatment of intertrochanteric fractures. Aseptic technique is vital for reducing postoperative complications, as intraoperative glove perforations increase the risk of surgical site infections. The aim of this study was to determine the incidence of surgical glove perforation during intramedullary nailing of intertrochanteric fractures and to identify surgery-specific steps at risk. A prospective series of 148 short intramedullary nail implantations was analysed. Intraoperative glove perforations and causative events were recorded. All gloves from the scrubbed surgical team were collected and examined for micro- and macroperforations. 1771 gloves were tested. A total of 341 perforations in 309 gloves were detected, resulting in an overall glove perforation rate of 17%. Surgeon experience had no influence on the overall incidence of glove perforations. Usage of the awl and insertion of the proximal locking screw resulted in 33.9% of all detected glove perforations. Perforation rate significantly increased with operative time (p = 0.003). Regular glove changing after surgery-specific risk-steps and during longer surgeries could decrease the rate of glove perforations during intramedullary nailing of intertrochanteric fractures and reduce the risk of potential septic contamination or even disease transmission for both, the surgeon, and the patient.
No takes yet. Share an insight, caveat, or question.
Santol et al. (2025) conducted an observational in Intertrochanteric fractures (n=148). Intramedullary nailing of intertrochanteric fractures was evaluated on Overall surgical glove perforation rate. During intramedullary nailing of intertrochanteric fractures, the overall surgical glove perforation rate was 17.4%, and the perforation rate significantly increased with longer operative times.
Synapse has enriched 10 related papers. Consider them for comparative context: