It is commonly assumed that within inundated sand the Skempton B value and P-wave velocity decrease with decrease in saturation. In centrifuge tests a common saturation procedure is to inundate the specimen with carbon dioxide while under a vacuum and then slowly introduce the viscous pore fluid. The B value and related saturation is difficult to measure in centrifuge models and P-wave velocity—saturation correlations have been used for this purpose. A laboratory emulation of centrifuge saturation procedures was made using a triaxial cell with top and bottom bender elements and a viscous methyl cellulose–water pore fluid. Contrary to expectations, the laboratory tests showed high P-wave velocities indicative of full saturation when B values were low. Numerical modeling of the laboratory tests indicated that if air bubbles within the pore fluid are numerous and closely spaced then there is a good correlation between saturation, B value, and P-wave velocity. However if the air bubbles are larger and only present in some of the pores then the P-wave velocity is not a good indicator of B value and average saturation. The laboratory tests also showed that placing the specimen under backpressure for several days increased saturation and related B values. It is suggested that this common laboratory procedure should be considered for saturating centrifuge test specimens.
No takes yet. Share an insight, caveat, or question.
Naesgaard et al. (2007) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: