The development of rapid and sensitive point-of-test devices for on-site monitoring of heavy-metal contamination has great scientific and technological importance. However, developing fast, inexpensive, and sensitive microarray sensors to achieve such a goal remains challenging. In this work, we present a DNA-nanostructured microarray (DNM) with a tubular three-dimensional sensing surface and an ordered nanotopography. This microarray enables enhanced molecular interaction toward the rapid and sensitive multiplex detection of heavy-metal ions. In our design, the use of DNA tetrahedral-structured probes engineers the sensing interface with spatially resolved and density-tunable sensing spots that improve the microconfined molecular recognition. A bubble-mediated shuttle reaction was used inside the DNM-functionalized microchannel to improve the target-capturing efficiency. Using this novel DNM biosensor, the sensitive and selective detection of multiple heavy-metal ions (i.e., Hg 2+, Ag +, and Pb 2+ ) was achieved within 5 min, the detection limit was down to 10, 10, and 20 nM for Hg 2+, Ag +, and Pb 2+, respectively. The feasibility of our DNM sensor was further demonstrated by probing heavy-metal ions in real water samples with a direct optical readout. Beyond metal ions, this unique DNM sensor can easily be extended to in vitro bioassays and clinical diagnostics.
No takes yet. Share an insight, caveat, or question.
Qu et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: