Key result
A simplified radio frequency ablation procedure using only two catheters achieved bi-directional complete block in 29 of 30 patients, with 0% recurrence of atrial flutter over 16 months.
Why the study?
Does a simplified two-catheter approach for radio frequency ablation achieve bi-directional block and prevent recurrence in patients with common atrial flutter?
Does a simplified two-catheter approach for radio frequency ablation achieve bi-directional block and prevent recurrence in patients with common atrial flutter?
A simplified two-catheter approach for common atrial flutter ablation is feasible and effective, achieving bi-directional block with no recurrences at 16 months.
May support simplified two-catheter ablation for common atrial flutter; leaves open randomized confirmation of efficacy and durability.
UNLABELLED: Intra-atrial conduction block within the inferior vena cava-tricuspid annulus isthmus (IVCT) has been shown to predict successful common atrial flutter ablation. However, its demonstration requires the use of several electrode catheters and mapping of the line of block. The aim of this study was prospectively to test the feasibility of a simplified ablation procedure using only two catheters. METHODS: Radio frequency (RF) ablation of common atrial flutter was performed in 30 patients with the sole use of a catheter for atrial pacing and a RF catheter. RF ablation lesions were created in the IVCT. Surface ECG criteria were used to monitor the conduction within the IVCT. The end point during low lateral atrial pacing was an increment in the interval between the pacing artefact and the peak of the R wave in surface lead II >50 ms and clockwise rotation of the P wave axis beyond -30 degrees and inferiorly. Then, the line of lesions was mapped during atrial pacing with the RF catheter. Additional RF lesions were applied if mapping disclosed a zone of residual conduction. Otherwise the procedure was stopped if mapping showed parallel double potentials all along the line. Finally, the block was reassessed with a 'Halo' catheter. RESULTS: Surface ECG criteria were met in 26 patients. Mapping the line of lesions showed a complete corridor of parallel double potentials in these 26 cases and in 3 of the 4 patients in whom ECG criteria were not met. Conduction evaluated with the Halo catheter showed bi-directional complete block in these 29 patients. After a follow-up of 16 +/- 4 months there was no recurrence of atrial flutter. CONCLUSION: Surface ECG criteria combined with mapping of the line of block demonstrate evidence of bi-directional IVCT block. This simplified RF ablation of common atrial flutter is feasible with a low recurrence rate.
No takes yet. Share an insight, caveat, or question.
Didier Klug (2001) studied Common atrial flutter (n=30). Simplified radio frequency ablation using two catheters was evaluated on Recurrence of atrial flutter. A simplified radio frequency ablation procedure using only two catheters achieved bi-directional complete block in 29 of 30 patients, with 0% recurrence of atrial flutter over 16 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: