Key result
Ruptured aneurysm (P=0.03) and the need for secondary therapy within 30 days (P<0.01) were significantly associated with non-compliance to follow-up after endovascular aneurysm repair.
Why the study?
Regular follow-up after EVAR is required to identify endoleaks or stentgraft migration, but non-compliance is common and underlying factors remain unclear.
What is the frequency of and what factors influence non-compliance to follow-up after endovascular aneurysm repair?
Cohort
What is the frequency of and what factors influence non-compliance to follow-up after endovascular aneurysm repair?
Over one-third of patients are non-compliant with post-EVAR follow-up, particularly those presenting with ruptured aneurysms or requiring early secondary interventions.
Answers are grounded in this paper and cite their sources.
Non-compliance to post-EVAR surveillance remains common; leaves open targeted strategies to improve adherence.
Objectives Regular follow-up after endovascular repair of aortic aneurysm is necessary to detect endoleak and/or migration of the stentgraft. However, absence or incomplete compliance to follow-up is common in this patient population. In this study we will analyse the frequency of non-compliance to post-EVAR follow-up and explore the underlying reasons. Methods All patients undergoing EVAR for infrarenal aortic aneurysm between 1st January 2011 and 31st December 2020 were included in this retrospective study. Absence of compliance to FU was defined as not showing up at the out-patient clinic; incomplete FU was defined as a surveillance gap of >18 months. Results and conclusion Non-compliance to follow-up was 35.9% (175 patients). In the multivariate analysis the patients who came with a ruptured aneurysm and patients who needed secondary therapy in the first 30 days more often did not comply with the FU protocol ( P = .03 and P < .01). Other studies have confirmed the low attendance to follow-up after EVAR.
No takes yet. Share an insight, caveat, or question.
Brunschot et al. (2023) conducted a cohort in Infrarenal aortic aneurysm. Ruptured aneurysm and secondary therapy within 30 days vs. Non-ruptured aneurysm and no secondary therapy was evaluated on Non-compliance to follow-up (p=P = .03 and P < .01). Ruptured aneurysm (P=0.03) and the need for secondary therapy within 30 days (P<0.01) were significantly associated with non-compliance to follow-up after endovascular aneurysm repair.