Key result
During on-pump cardiac surgery, low-frequency oscillations in photoplethysmogram and heart rate were functionally independent, with directional coupling observed from peripheral vessels to the heart.
Why the study?
The authors sought to investigate the properties and interaction of low-frequency heart rate variability and photoplethysmographic waveform variability when their hemodynamic connection is absent, as well as photoplethysmographic regulation without heart function.
Observational (n=10)
No
The study demonstrates that low-frequency oscillations in photoplethysmographic waveforms are independent of heart rate variability mechanisms and suggests a neurogenic coupling from peripheral vessels to the heart.
We studied the properties of low-frequency (LF) heart rate variability (HRV) and photoplethysmographic waveform variability (PPGV) and their interaction under conditions where the hemodynamic connection between them is obviously absent, as well as the LF regulation of PPGV in the absence of heart function. The parameters of HRV and finger PPGV were evaluated in 10 patients during cardiac surgery under cardiopulmonary bypass (on-pump cardiac surgery) with or without cardioplegia. The following spectral indices of PPGV and HRV were ertimated: the total spectral power (TP), the high-frequency (HF) and the LF ranges of TP in percents (HF% and LF%), and the LF/HF ratio. We assessed also the index S of synchronization between the LF oscillations in finger photoplethysmogram (PPG) and heart rate (HR) signals. The analysis of directional couplings was carried out using the methods of phase dynamics modeling. It is shown that the mechanisms leading to the occurrence of oscillations in the LF range of PPGV are independent of the mechanisms causing oscillations in the LF range of HRV. At the same time, the both above-mentioned LF oscillations retain their activity under conditions of artificial blood circulation and cardioplegia (the latter case applies only to LF oscillations in PPG). In artificial blood circulation, there was a coupling from the LF oscillations in PPG to those in HR, whereas the coupling in the opposite direction was absent. The coupling from the LF oscillations in PPG to those in HR has probably a neurogenic nature, whereas the opposite coupling has a hemodynamic nature (due to cardiac output).
No takes yet. Share an insight, caveat, or question.
Kiselev et al. (2020) conducted an observational in Patients undergoing on-pump cardiac surgery (n=10). On-pump cardiac surgery with or without cardioplegia was evaluated on Directional coupling between low-frequency oscillations in photoplethysmogram and heart rate. During on-pump cardiac surgery, low-frequency oscillations in photoplethysmogram and heart rate were functionally independent, with directional coupling observed from peripheral vessels to the heart.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: