Key result
Intracoronary gamma-irradiation increased follow-up minimum lumen area compared to placebo (2.9 vs 1.9 mm2), with a higher dose yielding an even larger area (4.0 mm2; P<0.005 for all).
Why the study?
Does intracoronary gamma-irradiation improve minimum lumen area and reduce neointimal hyperplasia in patients with long, diffuse in-stent restenosis lesions?
RCT (n=89)
Double-blind
Does intracoronary gamma-irradiation improve minimum lumen area and reduce neointimal hyperplasia in patients with long, diffuse in-stent restenosis lesions?
Absolute Event Rate: 2.9% vs 1.9%
p-value: p=<0.005
Higher-dose intracoronary gamma-irradiation is more effective than standard dose or placebo in reducing recurrent in-stent neointimal hyperplasia in long, diffuse ISR lesions.
Supports gamma-irradiation dosing for diffuse ISR; leaves open need for randomized trials before practice change.
BACKGROUND: The efficacy of coronary gamma-irradiation in preventing recurrent in-stent restenosis (ISR) is well established. However, brachytherapy may be less effective in very long, diffuse ISR lesions. METHODS AND RESULTS: We used serial intravascular ultrasound (IVUS) to study patients with long, diffuse ISR lesions (length, 36 to 80 mm) who were enrolled in (1) Long WRIST (Washington Radiation In-Stent Restenosis Trial), a double-blind, placebo-controlled trial of intracoronary gamma-irradiation (15 Gy at 2 mm from the source) and (2) high-dose (HD) Long WRIST, a registry that used a dose prescription of 18 Gy at 2 mm from the source. IVUS was performed using automated pullback (0.5 mm/s). Stent, lumen, and intimal hyperplasia were measured at 2-mm intervals. Complete postintervention and follow-up IVUS imaging was available in 30 irradiated and 34 placebo patients from Long WRIST and in 25 patients from HD Long WRIST. Stent length was longer in HD Long WRIST than in placebo or treated patients in Long WRIST (P=0.0064 and P=0.0125, respectively). Otherwise, baseline measurements were similar. At follow-up, the minimum lumen area was largest in the HD Long WRIST patients (4.0+/-1.4 mm(2)); areas were 2.9+/-1.0 mm(2) in irradiated patients in Long WRIST and 1.9+/-1.1 mm(2) in placebo patients in Long WRIST (P<0.005 for all comparisons). CONCLUSIONS: - Serial IVUS analysis shows that gamma-irradiation reduces recurrent in-stent neointimal hyperplasia in long, diffuse ISR lesions; however, it is even more effective when given at a higher dose.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2001) conducted an RCT in Long, diffuse in-stent restenosis (n=89). Intracoronary gamma-irradiation vs. Placebo was evaluated on Minimum lumen area at follow-up (p=<0.005). Intracoronary gamma-irradiation increased follow-up minimum lumen area compared to placebo (2.9 vs 1.9 mm2), with a higher dose yielding an even larger area (4.0 mm2; P<0.005 for all).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: