The performance of a roof mounted grid‐connected photovoltaic (PV) system in Northern Ireland was monitored over 3 years on annual, seasonal and monthly bases. The overall system performance was adversely affected by low insolation conditions; 19% of total incident insolation was absorbed at irradiance level below 200 W/m2and 67% below 600 W/m2, only 6·2% above 900 W/m2. In summer and winter, the PV and system efficiencies were 9·0 and 8·5%, and 7·8 and 7·5%, respectively and inverter efficiencies were 86·8 and 85·8%, respectively. The inverter for this particular system was oversized; 77% of the total DC energy produced when inverter's operating load was 50% of its rated capacity. The annual average monthly system performance ratio (PR) was 0·61 with seasonal variation 0·59 to 0·63. The average monthly PV, system and inverter efficiencies over the whole monitored period were 8·8, 7·6 and 86·8%, respectively. The main losses of the system were inverter DC/AC conversion loss, inverter threshold loss and low insolation loss.