Key result
A survey of 374 European laboratories found widespread use of high-sensitivity troponin methods, though a significant minority do not use the recommended 99th percentile upper reference limit.
Why the study?
The study was conducted as a multi-country audit to assess how well laboratories adhere to recommended guidelines for cardiac biomarker management in routine clinical practice across Europe.
Cross-Sectional (n=374)
Yes
Despite widespread use of high-sensitivity troponin assays in Europe, adherence to guideline-recommended 99th percentile thresholds and rapid diagnostic protocols remains suboptimal.
Suboptimal hs-troponin guideline adherence persists; leaves open whether targeted interventions improve implementation.
BACKGROUND: The CARdiac MARker Guideline Uptake in Europe (CAMARGUE) program is a multi-country audit of the use of cardiac biomarkers in routine clinical practice. METHODS: An email link to a web-based questionnaire of 30 multiple-choice questions was distributed via the professional societies in Europe. RESULTS: 374 questionnaires were returned from 39 countries, the majority of which were in northern Europe with a response rate of 8.2%-42.0%. The majority of the respondents were from hospitals with proportionately more responses from central hospitals than district hospitals. Cardiac troponin was the preferred cardiac biomarker, evenly split between cardiac troponin T (cTnT) and cardiac troponin I (cTnI). Aspartate transaminase and lactate dehydrogenase are no longer offered as cardiac biomarkers. Creatine kinase, creatine kinase MB isoenzyme, and myoglobin continue to be offered as part of the cardiac biomarker profile in approximately on 50% of respondents. There is widespread utilization of high sensitivity (hs) troponin assays. The majority of cTnT users measure hs-cTnT. 29.5% of laboratories measure cTnI by a non-hs method but there has been substantial conversion to hs-cTnI. The majority of respondents used ng/L and use the 99th percentile as the upper reference limit (71.9% of respondents). A range of diagnostic protocols are in use. CONCLUSIONS: There is widespread utilization of hs troponin methods. A significant minority do not use the 99th percentile as recommended and there is, as yet, little uptake of very rapid diagnostic strategies. Education of laboratory professionals and clinicians remains a priority.
No takes yet. Share an insight, caveat, or question.
Collinson et al. (2021) conducted a cross-sectional in Cardiac biomarker management (n=374). Cardiac biomarker utilization was evaluated on Utilization of cardiac biomarkers and adherence to guidelines. A survey of 374 European laboratories found widespread use of high-sensitivity troponin methods, though a significant minority do not use the recommended 99th percentile upper reference limit.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: